{
  "$schema": "http://cyclonedx.org/schema/bom-1.6.schema.json",
  "bomFormat": "CycloneDX",
  "specVersion": "1.6",
  "serialNumber": "urn:uuid:05c19f5d-1c64-509a-85d7-296dbb549b35",
  "version": 1,
  "metadata": {
    "supplier": {
      "name": "TuxCare",
      "url": [
        "https://tuxcare.com"
      ]
    }
  },
  "components": [
    {
      "name": "micrometer-registry-otlp",
      "purl": "pkg:maven/io.micrometer/micrometer-registry-otlp@1.9.17-tuxcare.1",
      "type": "library",
      "group": "io.micrometer",
      "bom-ref": "pkg:maven/io.micrometer/micrometer-registry-otlp@1.9.17-tuxcare.1",
      "version": "1.9.17-tuxcare.1",
      "pedigree": {
        "ancestors": [
          {
            "name": "micrometer-registry-otlp",
            "purl": "pkg:maven/io.micrometer/micrometer-registry-otlp@1.9.17",
            "type": "library",
            "group": "io.micrometer",
            "version": "1.9.17"
          }
        ]
      },
      "supplier": {
        "url": [
          "https://tuxcare.com"
        ],
        "name": "TuxCare"
      }
    }
  ],
  "vulnerabilities": [
    {
      "id": "CVE-2026-40983",
      "affects": [
        {
          "ref": "pkg:maven/io.micrometer/micrometer-registry-otlp@1.9.17-tuxcare.1"
        }
      ],
      "bom-ref": "urn:uuid:68863de7-1f18-5bdc-a6d7-48f13ef4c725",
      "analysis": {
        "state": "not_affected",
        "detail": "Vulnerability CVE-2026-40983 does not affect version 1.9.17-tuxcare.1 of io.micrometer:micrometer-registry-otlp. Micrometer version 1.9.17 is NOT affected by CVE-2026-40983. The vulnerability requires the Observation API architecture (ObservationRegistry, DefaultMeterObservationHandler, ObservationGrpcServerInterceptor, DefaultGrpcServerObservationConvention) which was introduced in version 1.15.0. Version 1.9.17 uses a completely different gRPC instrumentation mechanism (MetricCollectingServerInterceptor) that does not extract or tag peer.name/peer.port values at all, making the metric cardinality explosion attack impossible. The CVE's version range stating \"older versions than 1.15.0 are not affected\" is accurate in this case.",
        "justification": "code_not_present"
      }
    },
    {
      "id": "CVE-2026-40984",
      "affects": [
        {
          "ref": "pkg:maven/io.micrometer/micrometer-registry-otlp@1.9.17-tuxcare.1"
        }
      ],
      "bom-ref": "urn:uuid:2f57a0f5-6024-5354-ac78-1b61362dceaf",
      "analysis": {
        "state": "exploitable",
        "detail": "Vulnerability CVE-2026-40984 affects version 1.9.17-tuxcare.1 of io.micrometer:micrometer-registry-otlp."
      }
    },
    {
      "id": "CVE-2026-59295",
      "affects": [
        {
          "ref": "pkg:maven/io.micrometer/micrometer-registry-otlp@1.9.17-tuxcare.1"
        }
      ],
      "bom-ref": "urn:uuid:d7062d1e-ab1b-5db1-b53e-2d491d572003",
      "analysis": {
        "state": "resolved",
        "detail": "Vulnerability CVE-2026-59295 is fixed in version 1.9.17-tuxcare.1 of io.micrometer:micrometer-registry-otlp."
      }
    },
    {
      "id": "CVE-2026-59296",
      "affects": [
        {
          "ref": "pkg:maven/io.micrometer/micrometer-registry-otlp@1.9.17-tuxcare.1"
        }
      ],
      "bom-ref": "urn:uuid:cdb1eb75-bb25-5e5e-892f-4b3f60069965",
      "analysis": {
        "state": "resolved",
        "detail": "Vulnerability CVE-2026-59296 is fixed in version 1.9.17-tuxcare.1 of io.micrometer:micrometer-registry-otlp."
      }
    }
  ],
  "dependencies": [
    {
      "ref": "pkg:maven/io.micrometer/micrometer-registry-otlp@1.9.17-tuxcare.1"
    }
  ]
}